Skip to content

Viewing Windows Event Viewer PCoIP Agent Logs

You can view high-level session and connection events generated by the PCoIP agent and Anyware Manager in the Windows Event Viewer.

PCoIP Agent Events

To view events using the Windows Event Viewer:

  1. Navigate to Start > Control Panel > System and Security > Administrative Tools and double-click Event Viewer.

  2. Navigate to Event Viewer (Local) > Windows Logs, right-click Application, and select Filter Current Log.

  3. In the Event sources drop-down list, select PCoIPAgentService and click OK.

  4. Select an event to view its details.

The next example shows typical PCoIP agent session and connection events that you can view in the Windows Event Viewer.

windows event viewer

Key events to watch for in the event viewer logs:

Event ID Key Notes
88 SESSION_START
89 SESSION_END
90 LAUNCHER_EXIT
91 CONNECTION_TIMEOUT
92 CONNECTION_FAILURE
93 SESSION_REDIRECTION
94 SESSION_INTERRUPTION
95 SERVICE_STARTING PCoIP  Agent service starting.
96 SERVICE_STOPPING PCoIP  Agent service stopping.
97 SESSION_RESUMING
98 VIDEO_DRIVER_REPAIR_ERROR
99 FLEXERA_SERVICE_ERROR
100 VCHAN_LOADER_EXCEPTION  An exception was thrown in a PCoIP virtual channel plugin.
101 NO_AGENT_ERROR The PCoIP agent process could not be detected.
102 VCHAN_LOADER_INTERNAL_ERROR An internal error has occured.
103 VCHAN_LOADER_BAD_INVOCATION_ERROR The PCoIP virtual channel loader utility was invoked incorrectly.
104 AGENT_PROCESS_TERMINATED_ERROR The PCoIP Agent process was terminated.
105 SSO_PIPE_CREATION_ERROR The Single Sign On framework was unable to establish a secure connection with the Teradici Agent.
106 MANUAL_DISCONNECT The PCoIP session was disconnected by the user.
107 USER_SIGNOUT_SWITCH The PCoIP session was disconnected by a user logout or user switch.
108 SHUTDOWN_RESTART_SLEEP The PCoIP session was disconnected by a machine shutdown, restart, or sleep event.
112 SERVICE_START_ERROR PCoIP  Agent service cannot be started.
113 SERVICE_INTERNAL_ERROR
114 SERVICE_ADMINISTRATIVE_MESSAGE
115 SERVICE_SHUTDOWN A shutdown of the server machine was initiated.

Anyware Manager Events

If you are using Anyware Manager to start and stop your host machines, the CAMIdleShutdown process will log events as well. Follow the same procedure

Event ID Description
95 CAM Idle Machine Shutdown service starting
96  CAM Idle Machine Shutdown service stopping
114 Machine will be checked for idle state.
115 Shutting down idle machine.